Rescue life detector parameters and procedures
| Product Overview: Life Detector is a rugged portable device for detecting survivors under collapsed buildings after a natural disaster. It uses the principle of ultra-wideband ( UWB ) ground penetrating radar to detect active targets within 12 meters and respiratory behavior within 10 meters. | |||||||||
Features | 1 Search Optimization: Quickly identify survivors and detect breathing almost instantaneously 2 Easy to use: The user-selectable graphical interface indicates detected motion and breathing by using icons. The rescue team can master the operation of the life detector within a few hours. 3 portable: portable, individual and easy to operate Dual receivers in the 4 system provide excellent data acquisition capabilities and increase the reliability of the test | |||||||||
product structure | Dual receiver Reinforcement protection design Ergonomically designed handle Wifi connection antenna Pad display controller Easy to use graphical interface | |||||||||
Product parameters |
| |||||||||
Precautions | 1. It is strictly forbidden to open fire or exceed |
Life jacket technical parameters and usage procedures
| Product Overview: For professional rescue work in rivers, lakes and seas | |
Scope of application | Suitable for use by all types of personnel in coastal and inland rivers | |
Buoyancy | Buoyancy greater than 7.5kg | |
material | Polyethylene foam | |
Use procedure | Wear directly | |
Precautions | After soaking in water for 24 hours, the buoyancy loss should be less than 5% . | |
Inspection and maintenance | Check once a month, no damage, ensure its complete and easy to use |
Lifebuoy technical parameters and use procedures
| Product Overview: For professional rescue work in rivers, lakes and seas | |
Scope of application | Suitable for use by all types of personnel in coastal and inland rivers | |
Buoyancy | Outside diameter 710mm Internal diameter 440mm Capable of supporting not less than 14.5kg of iron in fresh water up to 24h years Has a mass of not less than 2.5kg | |
material | Polyethylene | |
Use procedure | Direct wear applies | |
Precautions | After soaking in water for 24 hours, the buoyancy loss should be less than 5% . | |
Inspection and maintenance | Check once a month, no damage, ensure its complete and easy to use |
Strong light flashlight parameters and usage procedures
| Product Overview: Used for Lighting in Emergency Rescue | |||||||||||||||||||
Product parameters |
| |||||||||||||||||||
Precautions | Check to ensure binding between the lamp tube and the front cover and the back cover closely to enhance waterproof, explosion and impact resistance. When charging in a place with high ambient temperature or continuous discharge with strong light for a long time, a slight temperature rise on the surface of the flashlight is a normal phenomenon. It is forbidden to open the lamp and place the transparent part of the lamp face down; do not disassemble the structural parts of the lamp, especially the sealing structure. | |||||||||||||||||||
Inspection and maintenance | Check once a day to ensure that it has enough power |
Insulation service and use procedures
| Product Overview: A kind of protective clothing worn by firefighters during combat in fire fighting and emergency rescue near high temperature or high heat radiation area. | |
Performance parameters | â— With reference to the European EN1486 standard â— Comprehensive application of high-tech materials such as KEVLAR , NOMEX , PANOX and KERMEL â—It has the advantages of flame retardant, heat insulation, folding resistance, anti-radiation heat, etc. â— Suitable for a variety of high temperature and high heat radiation operation of the industrial environment, especially in metallurgy, forging, petroleum, chemical and other industries â— The whole set of clothing includes: hood, tops, bib, gloves, foot cover | |
Precautions | Keep clean, store in a dry, ventilated environment, avoid crushing, avoid contact with sharp objects, not over-temperature use | |
Inspection and maintenance | Check once a month, keep it clean and avoid crushing |
Gas Mask Fire Parameters and Procedures
| Gas masks are used as personal protective equipment to provide effective protection for the respiratory organs, eyes and facial skin of personnel. The mask can be used directly with a canister, or it can be used with a canister to connect to a canister. | |
Performance parameters | Protection targets: According to the need to select different canisters, can protect a variety of toxic gases, vapors and poisonous smoke; Expiratory resistance: not more than 98 Pa ( 30 liters / min); Field of vision: total visual field not less than 70% , binocular field of view not less than 30% ; Baoming performance: 1.5 hours or more lenses do not fog, distortion, deformation ( -30 . C ) Air tightness (oil mist leakage coefficient): not more than 0.005% . | |
Precautions | Avoid squeezing and touching sharp objects | |
Inspection and maintenance | Check once a month, keep it clean, and seal it. | |
This article was edited by China Rescue Equipment Network.
Gate Valve
Gate Valve,Sealing Gate Valve,Stainless Steel Gate Valve,Flanged Knife Gate Valve
Ningbo RMI Plastic Co., Ltd. , https://www.rmiplast.com