Digital display force gauge correct use

The digital force gauge is an indispensable force measuring instrument in our daily life. In the process of using a digital force gauge, the correct use method is very important for the digital force gauge. The push-pull dynamometer not only can prolong the service life of the instrument, but also can reduce the chance of failure. The following is a brief introduction of the digital push-pull force gauge Xiaobian to introduce the correct use of the digital push-pull force gauge:
Digital push-pull force meter use method:
1, before use, first check the battery voltage is normal, if under voltage, please charge in time, otherwise the measurement will appear deviation.
2. Estimate the measurement size, select the appropriate range of digital push-pull force meter, and measure the out-of-range range, which will result in the damage of the digital push-pull sensor.
3. If the measured value is lower than 3% of the digital push-pull measuring range, the accuracy will be deviated.
4. If you do not use it for a long time, you should periodically charge the digital power meter.
5. At the same time, when the weather is humid in the summer, digital display push force gauges should be used to preserve the environment and digital display push force meters should be protected from corrosion.
Note: After the digital push-pull gauge is used, the surface should be wiped clean. Do not put any items on the digital push-pull gauge.
Each digital force gauge instrument, its use and the use of the environment will directly affect the life of the digital display force gauge, so we must understand the use of digital force gauge and some functions, which can reduce the digital display Push force meter product damage / maintenance rate oh.
The following describes the functions of some digital push-pull gauges for users. We hope that users can correctly use the digital push-pull gauges after understanding.
1. Digital push-pull meter data storage and memory clearing
a. Store data
Only in the peak hold state, after the digital push-pull force test is completed, press the MEMO key to save the test value. The display will have the MEM display and the stored memory data can be turned off when the power is turned off. When you use the DATA key to view the memory data, the MEM flashes, the number of memory appears first, and the memory value automatically appears after 2 seconds. Press the ZERO key to exit the memory and enter the test directly.
b. memory clear
In the normal working state of the instrument, press the ZERO key for more than four seconds, all the memory data will be cleared, and the MEM word disappears, indicating that no data is stored in the instrument.
2. Change in gravitational acceleration value
You can input the gravitational acceleration value of the place you are using. Press and hold the PEAK key and hold the ON key to enter the gravitational acceleration setting interface. After entering the new gravitational acceleration value, press the SET key to automatically shut down the instrument. Reboot to use.
3 digital push pull test
a. Turn on the power and turn on: In the off state, turn on the power and press the instrument ON button to turn on the power. After the power is turned on, the instrument first enters the self-test procedure, and the screen swears HANDPI words and displays the model of the machine, and the instrument can enter the normal working state.
b. Select the appropriate measuring force and install it on the digital push-pull force meter with the connector type (for self-made jigs, please refer to the relevant data in “Contour and Installation Dimension”).
c. Please firmly hold the digital push-pull force meter or install the digital push-pull force meter on a suitable tester to test. Please test the force and push-pull rod push-pull rod in a straight line to measure The exact load value.
d. After completion of the digital push-pull gauge test, remove the load, turn off the power, remove the equipment, clean the items and put them back into the tool box, and use it for the next generation.

Product Name:  Highest Standard Qualtiy  far infrared wall carbon cystal Panel Heater
Heating Element:  Carbon crystal 
Power:  350W±5%
Voltage:  220V-240V / 50Hz
Certification:  CE,RoHS,IP65
Using life:  50-55years span
Infrared radiant wavelength:  8~15um
Electric heat radiation conversion rate:  >98%
Surface temperature:  95-105 celsius degree
Installation type:  wall mounted . ceiling ,free standing
Function:  Adjustable Thermostat, Overheat Protection
Insulation class:  IP56

Wall Mounted Radiant Heater

Wall Mounted Radiant Heater,Wall Mounted Heater,Electric Radiant Heaters,Electric Radiant Heater Wall Mounted

Shandong Dexiang Electrical Technology Co.,Ltd , https://www.heater-kerosene.com

This entry was posted in on