Torque tester operation method

Torque tester is a very popular torque instrument, many people buy, but recently the salesman's salesman will always receive a phone call asking how the torque tester operates. It is found that many users do not understand the operation of the torque tester. The problems that arise during the operation are also bizarre. For this reason, hard-working Xiaobian has compiled a document for the operation of the torque tester, hoping to help everyone.

Digital torque tester operation method:

First of all: Before using the digital torque tester, check whether the power of the instrument is sufficient. If the power is insufficient, please charge first (can also be used when charging).

Second: Put the square probe of the object under test into the square hole of the tester, and use the handle at the other end of the object above the height adjustment block (if the length is not enough, you can freely adjust the whole loading device ).

Third: Turn on the power switch and the displayed torque value is zero. If it is not zero, press the clear key to clear the torque value.

Finally: before the test, the first need to set the upper and lower limit values, the minimum storage value, the minimum peak hold value, the automatic peak time, automatic shutdown time, gravity acceleration and so on.

1. Upper limit value setting: The user sets the upper limit value and set it freely according to the need. The upper limit value is the automatic sound and light prompt. The upper limit value is not higher than the full scale.

2. Lower limit value setting: The user sets the lower limit value, and it can be set freely according to the need. The lower limit value is the automatic light prompt, and the lower limit value cannot be higher than the set upper limit value.

3. Minimum storage value setting: The user sets the minimum storage value according to storage requirements, and data smaller than this value will not be stored.

4. Minimum peak hold value setting: According to the peak value, the user needs to set the automatic peak measurement freely, and the data less than this value is not saved by the peak value.

5. Automatic peak time setting: The user can freely set from 1 second to 99 seconds according to the time required for the peak value in the automatic peak measurement state.

6, automatic shutdown time setting: No operation, automatic shutdown time from 0 minutes to 9 minutes can be freely set (when set to 0 minutes, it means to lift the automatic shutdown).

7. Gravity acceleration setting: The user can set the gravity acceleration value according to the location of this area. The default is 9.794.

8. Restore the initial settings: If the user does not operate properly or changes the data several times, you can use this setting to restore the data from 1 to 7 to the factory state.

I hope the above article is helpful to you.
Guess what you also like: digital push-pull force meter torque wrench tester torque tester torque wrench price fixed torque electric wrench digital torque tester test bench

Cement Tray

After-sale Service: Online technical support, Return and Replacement, Other

Processing: cement concrete

Project Solution Capability: graphic design, 3D model design, total solution for projects, Others

Application: Hotel

Design Style:Modern

Place of Origin:Guangdong, China

Brand Name: Duraplex

Type:Countertop Sinks

Special Application:counter top washbasins

Stone Type:cement

Material:cement

Shape:Retangular Basin

Packing:5 Layers Carton Box

Delivery time:Within 30 Days

Basin type:Wash Sink

Style:Modern Desgin

OEM:Acceptable

cement washing basin, cement mixing basin, cement tray bathroom, cement basin bathroom, cement basin sink

Duraplex Limited , https://www.fsduraplex.com

This entry was posted in on