High temperature gear pump including KCG, 2CG high temperature gear pump. This series of high temperature gear pump gear, shaft, pump cover, shaft seal and other components, all parts are made of suitable temperature-resistant materials. Pump running parts are transported using the media lubrication. KCG, 2CG high temperature gear pump with safety valve to prevent overloading on the pump and motor damage. High temperature gear pump lock the process of working Reason for the failure: coupling eccentric or poor lubrication; motor failure; arc gear pump shaft seal installed poor; shaft deformation or wear; medium viscosity is too large.