In northern China, especially in the northeast region, the winter temperatures will drop to minus tens of degrees in the winter. In this case, the general power cable has a short construction period during construction, and the outer sheath of the cable becomes brittle, easily cracked, and bends. Weakening and many other disadvantages, forced construction will easily lead to huge material waste and safety hazards. Therefore, special cold-resistant and anti-freeze cables must be used.
Cold-resistant cable use characteristics Long-term allowable operating temperature of cable conductors:
PVC or polyethylene insulated cold-resistant cables: The maximum allowable operating temperature for cable conductors is 70 °C. The maximum temperature of the cable conductor does not exceed 160°C in the event of a short circuit (maximum duration not exceeding 5 s).
Cross-linked polyethylene insulated cold-resistant cables: The maximum allowable operating temperature for cable conductors is 90 °C. The maximum temperature of the cable conductor does not exceed 250°C in the event of a short circuit (maximum duration not exceeding 5 s).
The minimum cold-resistant temperature of the cable is -60°C; the temperature of the cable used in the outdoor environment for long-term operation is -60°C to +40°C. Allow the cable to be connected to the electrical equipment and to be removed under the appropriate cold temperature rating. When wiring and disconnecting, slowly bend the cable. The bending radius is 5 times the cable diameter. There should be no impact on the cable during operation.
Cold-resistant cable product advantages and characteristics
The cold-resistant cable has excellent cold resistance and can be installed and used normally in cold winter conditions. In the ultra-low temperature state, even if it is affected by external forces, the outer jacket of the cable still has good physical, mechanical, electrical and anti-aging properties, will not crack, and greatly improve the safety and service life of the cable. The general performance of cables such as electrical and mechanical properties fully comply with the requirements of national standards; their special performance indicators: under the corresponding rated low temperature conditions (-40°C, -45°C, -50°C, -55°C and -60°C), The low temperature winding test does not crack, the elongation at the low temperature tensile test is at least 20%, and the low temperature impact test does not crack.
Cold-resistant cable use characteristics Long-term allowable operating temperature of cable conductors:
PVC or polyethylene insulated cold-resistant cables: The maximum allowable operating temperature for cable conductors is 70 °C. The maximum temperature of the cable conductor does not exceed 160°C in the event of a short circuit (maximum duration not exceeding 5 s).
Cross-linked polyethylene insulated cold-resistant cables: The maximum allowable operating temperature for cable conductors is 90 °C. The maximum temperature of the cable conductor does not exceed 250°C in the event of a short circuit (maximum duration not exceeding 5 s).
The minimum cold-resistant temperature of the cable is -60°C; the temperature of the cable used in the outdoor environment for long-term operation is -60°C to +40°C. Allow the cable to be connected to the electrical equipment and to be removed under the appropriate cold temperature rating. When wiring and disconnecting, slowly bend the cable. The bending radius is 5 times the cable diameter. There should be no impact on the cable during operation.
Cold-resistant cable product advantages and characteristics
The cold-resistant cable has excellent cold resistance and can be installed and used normally in cold winter conditions. In the ultra-low temperature state, even if it is affected by external forces, the outer jacket of the cable still has good physical, mechanical, electrical and anti-aging properties, will not crack, and greatly improve the safety and service life of the cable. The general performance of cables such as electrical and mechanical properties fully comply with the requirements of national standards; their special performance indicators: under the corresponding rated low temperature conditions (-40°C, -45°C, -50°C, -55°C and -60°C), The low temperature winding test does not crack, the elongation at the low temperature tensile test is at least 20%, and the low temperature impact test does not crack.
Shower mixing valve
Shower Mixer valve is made of H59 brass, gravity casting, ceramic cartridge, 500,000 cycles no leakage. Shower diverter valve is a part of a Concealed Shower Mixer set. The new diverter valve is using one key dual control program, and protected by integrated embedded box, which is convenient to installation and maintaining.
Shower Mixing Valve,Thermostatic Shower Mixer Valve,Shower Mixer Valve,Thermostatic Mixing Valve
SHENZHEN KING OF SUN INDUSTRY CO.,LTD , https://www.handybasinfaucet.com