Regarding the difference between the centrifugal fan and the axial fan, we need to understand it before we can know how to use it and make full use of its resources. 1 Because the temperature and grain temperature are quite different, the first ventilation time should be selected during the day to reduce the gap between grain temperature and temperature and reduce the occurrence of condensation.
Zhejiang Juli Fan News: Regarding the difference between centrifugal fan and axial fan, we need to understand it before we can use it properly and make full use of its resources. 1 Because the temperature and grain temperature are quite different, the first ventilation time should be selected during the day to reduce the gap between grain temperature and temperature and reduce the occurrence of condensation. The ventilation should be selected at night as much as possible, because the ventilation is mainly based on cooling, the atmospheric humidity is relatively high at night, and the temperature is low, which reduces the water loss, and makes full use of the low temperature at night to improve the cooling effect. .
2In the initial stage of ventilation with centrifugal fan, there may be condensation on doors, windows and walls, and even the surface of the grain is slightly dew. Just stop the fan, open the window, open the axial fan, turn the grain surface if necessary, and remove the hot and humid air in the warehouse. It can be outside. When the axial fan is used for slow ventilation, there will be no condensation. Only the middle and upper grain temperature will rise slowly. As the ventilation continues, the grain temperature will drop steadily.
3 When the axial flow fan is used for slow speed ventilation, the air volume of the axial flow fan is small, and the grain is a poor conductor of heat. In the initial stage of ventilation, the ventilation of individual parts is slow, and the grain temperature will gradually balance as the ventilation continues.
4 The food that is slowly ventilated must be cleaned by vibrating screen, and the grain that enters the bin must be cleaned in time to the impurity zone caused by automatic classification, otherwise it may cause local ventilation unevenness.
5 Energy consumption calculation: The total flow of the axial fan of No. 14 warehouse is 50 days, with an average of 15 hours per day, sharing 750 hours, the average moisture is reduced by 0.4%, the grain temperature is reduced by 23.1 degrees, and the unit energy consumption is 0.027kw. h/t.°C. The warehouse No. 28 was ventilated for 6 days, sharing 126 hours, the water was reduced by 1.0% on average, the temperature was reduced by 20.3 degrees, and the unit energy consumption was 0.038kw.h/t.°C.
6 Advantages of slow-flow ventilation with axial flow fan: good cooling effect; low energy consumption per unit, especially important in advocating energy saving; ventilation timing is easy to master, condensation is not easy to occur; no separate fan is needed, convenient and flexible. Disadvantages: Because the air volume is small, the ventilation time is long; the precipitation effect is not obvious, and the high water content grain should not be ventilated by the axial flow fan.
Advantages of 7 centrifugal fan: The effect of cooling and precipitation is obvious, and the ventilation time is short; Disadvantages: the unit energy consumption is high; the ventilation timing is not easy to be exposed.
8 Conclusion: In the ventilation for the purpose of cooling, the axial flow fan is used for safe, efficient and energy-saving slow ventilation; the centrifugal fan is used in the ventilation for the purpose of precipitation.
Source of information: Zhejiang Juli Fan Co., Ltd. http:// Welcome to reprint
Http://news.chinawj.com.cn Editor: (Hardware Business Network Information Center) http://news.chinawj.com.cn
Office Partition Aluminium Profiles
So why is aluminum profile popular? Why do you choose aluminum profile to customize this office partition?
Firstly, because the hardness of aluminum profile is relatively high, it is not easy to deform, and the landing is relatively stable, the surface of aluminum profile is anodized with a thickness of 12 microns to form a tenacious oxide film. The surface is very beautiful, and the anti-corrosion performance is relatively good. The partition of the office is customized with aluminum profile. The connection mode adopted is the connection of accessories, that is, special aluminum profile accessories. There is no need for installation, seamless connection, and disassembly and installation are very convenient; Aluminum profile has smooth surface, simple maintenance, long service life and can be recycled; The cost performance of aluminum profile office partition is very high, which is better than stainless steel and ordinary steel.Office Partition and door,Office Wall,Fireproof Aluminum Office Partition Profile,Top Industrial Office Wall.
Office Partition Aluminium Profiles,Office Partition And Door,Top Industrial Office Wall,Office Partition Walls With Doors
GuangDong XinCheng Material CO.,LTD , https://www.xin-alu.com